Familiar patterns for a new 3D heart-mapping system

A three-month sprint designing the interface around Kodex’s live 3D heart map. I adapted the conventions doctors already knew from other mapping systems, built a design system, and stayed on to support the build.

ROLE

Product Designer · Contractor

team

PM, Unity Developer, EP Engineers, Analyst

TIMELINE

2018 · 3-month sprint, then build support

Status

Shipped · HRS 2019

All Work

EPD Solutions · Kodex

Familiar patterns for a new 3D heart-mapping system

A three-month sprint designing the interface around Kodex’s live 3D heart map. I adapted the conventions doctors already knew from other mapping systems, built a design system, and stayed on to support the build.

ROLE

Product Designer · Contractor

team

PM, Unity Developer, EP Engineers, Analyst

TIMELINE

2018 · 3-month sprint, then build support

Status

Shipped · HRS 2019

All Work

EPD Solutions · Kodex

Familiar patterns for a new 3D heart-mapping system

A three-month sprint designing the interface around Kodex’s live 3D heart map. I adapted the conventions doctors already knew from other mapping systems, built a design system, and stayed on to support the build.

ROLE

Product Designer · Contractor

team

PM, Unity Developer, EP Engineers, Analyst

TIMELINE

2018 · 3-month sprint, then build support

Status

Shipped · HRS 2019

TL;DR

Kodex is EPD Solutions’ system for steering a catheter through a live 3D map of the heart. In an early pilot, specialists pushed back on how the first version’s screen behaved. In a three-month contract sprint I adapted the conventions doctors already knew from other mapping systems, built a design system, and supported implementation through QA and lab testing. Kodex was shown at HRS in February 2019, and Philips acquired EPD Solutions five months later.

Context

A new 3D system for doctors with years of habits.

Kodex maps a patient’s heart in live 3D so a cardiologist can steer a catheter inside it. The 3D was new. The doctors using it weren’t: they’d spent years in other mapping systems, and the first version asked them to set all of that aside.

The problem

The screen got in the doctors’ way.

In an early pilot, EPD’s team walked heart-rhythm specialists through the first version of Kodex. Their feedback wasn’t about what the technology could do. It was about how the screen behaved.

The first version of Kodex: a game-engine fly-through and a 3D map in panes locked side by side, with no live readings.

USABILITY ISSUES FROM THE PILOT

Free-flying camera

01 Unnatural navigation

The camera free-flew like a first-person shooter, nothing like a catheter moves. The Unity developer and EP engineers reworked it.

Fixed split

02 Locked in place

Every panel was fixed. But each doctor, and each step of a procedure, needs different information up front.

No live readings

03 Missing live feedback

The readings that confirm a treatment is working weren’t on screen when doctors needed them.

The 3D team took navigation. The other two lived in the interface, and those were mine.

Approach

Familiar beats novel.

Familiar beats novel.

With three months and a convention deadline, inventing a new interface language was the wrong bet. I studied the mapping systems these doctors already used and adapted their conventions: where the signals sit, how the views split, which actions stay in reach. New patterns went in only where Kodex itself was new.

WHAT DOCTORS ALREADY WORKED IN

Rhythmia HDx · Boston Scientific

EnSite X · Abbott

CARTO 3 · Biosense Webster

CardioInsight · Medtronic

THE LAYOUT THEY SHARE

Controls along the edge

Signal rail

3D map

colour scale · orientation cue

Second view

Live readout · CL · LAT · Imp

Each region appears in at least two of the four systems. Teal marks the patterns I carried into Kodex; the 3D map itself belonged to the 3D team.

KEPT IN KODEX

Dark canvas

02 Legibility

Signal rail beside the map

01 Layout

A second view alongside

01 Layout

Live readout always on screen

01 Layout

Controls grouped at the edges

03 Quick actions

01 · Layout

A layout doctors already recognize.

I kept the arrangement common to cardiac mapping systems: the heart-signal rail, two map views, a live readout and the main controls. Unlike the pilot version, the regions resize and collapse, so the screen can follow each step of the procedure.

THE KODEX SCREEN, REGION BY REGION

1

2

3

6

1

ECG / waveform rail

2

View 1 — 3D map

3

View 2 — Pano map

4

Acquire control

5

Live readout (CL · LAT · Imp)

6

Projection toolbar

ONE SCREEN, SET UP FOR EACH STEP

ECG

3D

Pano

Default

ECG 24 · 3D 38 · Pano 38

3D

Pano

Maps side by side

3D 50 · Pano 50

ECG

Signals full width

ECG 100

3D

Pano

ECG

Rail on the right

3D 38 · Pano 38 · ECG 24

02 · Legibility

Readable from across the room.

Doctors often read this screen from about two meters away, hands busy, mid-procedure. A dark interface cuts the glare of staring into a bright screen for hours. On top of it, a strict type hierarchy and large readouts let them catch values at a glance.

READ AT A GLANCE, FROM TWO METERS

1

2

3

4

1

Readout values set at about twice the size of their labels

2

Main actions as large round targets: START and CHECK

3

View shortcuts as plain, widely spaced text

4

Dark panels on a black canvas, to cut the glare of a bright screen

03 · Quick actions

Critical actions within reach.

The most-used actions sit in a floating toolbar with presets doctors can save. The default order followed rival systems, so it felt right before anyone changed a thing.

THE FLOATING TOOLBAR AND PRESETS

1

2

3

4

1

Map tools stacked in one floating column

2

View controls and Reset in a single row

3

Preset 1–3 bring back a saved view

4

Save 1–3 store the current view

Handoff

Built to be handed off.

I set up a design system early: one home for color, type and components. After the sprint I stayed on through implementation, supporting QA engineers and lab testing with the advisory physicians. In-house designers later took the product forward from there.

REUSABLE INTERFACE LANGUAGE

START

CHECK

Static

LAT

LM

Auto LAT

Default

PANO Presets

▾

Preset 1

Preset 2

Save 1

Save 2

1000

msec

CL

-136

msec

LAT

79

ohm

Imp

Cone

Cross

✓

CL Stability

Opacity

77%

✕

START

LAT ----------------

Static

LAT

LM

Auto LAT

1

2

3

4

5

6

PANEL ANATOMY

1

Title bar

Lighter strip, close button on the right

2

Surface

Midnight Blue #263341

3

Primary action

Large round button for the panel’s main task

4

Status line

The panel’s current reading

5

Mode buttons

Round buttons of equal weight

6

Setting

Label with a toggle

Black

#151C27

Midnight Blue

#263341

Cornflower Blue

#7DA0D4

Cadet Blue

#179CB7

Gainsboro

#E2E2E3

AV node

His

Pace

PVC

Fragmented

Vagal Response

What happened next

Shown at HRS, then acquired.

My part ended when in-house designers took over, so I don’t have usage data from the field. What’s public is the timeline: Kodex was shown at the HRS cardiology convention in February 2019, and five months later Philips acquired EPD Solutions.

2018

3-month design sprint, then build support

FEB 2019

Shown at the HRS cardiology convention

JUL 2019

Philips acquired EPD Solutions for $293M

The acquisition was about the product and the company, not this interface. Kodex later appeared in a 2023 peer-reviewed clinical study (Frontiers in Cardiovascular Medicine).

Reflection

Knowing when not to invent.

Physicians are a hard audience for a new tool. They’ve built years of muscle memory on systems they trust, and in the middle of a procedure there’s no room to learn something unfamiliar. Kodex taught me that with experts like these, adoption starts with recognition: keep what they already know, and introduce something new only where the technology itself demands it. It changed where I start: with the tools people already rely on, before drawing anything new.